Menu Close

RICE LAKE CANISTER LOAD CELL, IN STAINLESS STEEL, “RL5426” SERIES

Category:
  • CONNECTION
    Cable Color Code
    RED
    INPUT +
    BLACK
    INPUT –
    GREEN
    OUTPUT +
    WHITE
    OUTPUT –
    YELLOW
    SENSE +
    BLUE
    SENSE –
    METAL
    Shield
  • INSTALLATION KIT
  • The 173798 kit allows a correct installation of the RL5426 load cells below the weighbridge plate.
  • The kit consists of an upper cup and a lower cup with anti-rotation system. All components are made from stainless steel. Both cups are designed for optimal operation in conjunction with the cell’s self-centering spherical bases, allowing their proper oscillation and return to position.
  • TECNICAL FEATURESMETROLOGICAL FEATURES
  • Rated capacity: (FS): 20t, 30t, 50t
  • Combined error: 0,015 %F.S
  • Creep error (after 30 min.): 0,01 %FS
  • Temperature effect on zero: 0,01 %F.S./5°C
  • Temperature effect on sensitivity: 0,008 %F.S./10°COIML R60
  • Vmin= Emax/18000
  • Accuracy class: C6
  • Max. number of intervals: 6000e OIMLELECTRONIC\MECHANICAL FEATURES
  • Gas dischargers to protect against atmospheric discharges
  • Power Supply: 5÷15 Vdc
  • Rated output at F.S.: 2 ± 0.1% mV/V
  • Input resistance: 800 ± 3Ω
  • Output resistance: 700 ± 3Ω
  • Insulation resistance: 5000MΩ
  • Operating temperature: -35 ~ +70 °C
  • Compensated temperature for homologation: -10 ~ +40 °C
  • Storage temperature limits: -40° ~ +80°
  • Normal service: 120% F.S.
  • Maximum load / Safe load: 150% F.S.
  • Ultimate overload: 300% F.S.
  • IP69K protection degree
  • Stainless steel body
  • 6-core cable, l= 20 m, 6,5mm diameter
  • Nickel plated steel cable gland
  • Self-centring spherical bases
  • Equipped with anti-rotation system, to be combined with 173798 cups for proper operation
DOWNLOAD
Available versions
Code Max
(kg)
177961  20 000
177963  30 000
177965  40 000
177967  50 000

 

Assembly kits
Code Description
173798 Kit of 2 jointed cups for selfalignment, in stainless steel. For RL5426xx load cells.

 

Junction Box / Boards – Cell cables
Code Description
JB10Q Equalisation box for connection with up to 10 analogue load cells. Reinforced polyester box, with 10 + 1 cable glands. With surge arresters, PCB, Terminal block, plastic box and UL marked labels (if applicable).
LCCB Shielded 6×0,25 mm² cable (suitable for Ex zones). €/m
LCCBA Armoured cable 6×0.25 mm². PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 °C. Minimum bending radius >/= 5 x O.D. €/m

 

Protection for junction box/electronic circuits
Code Description
GELBOX (S1) Anti condensation, insulating, and sealing gel. Useful to protect the electronic circuits of the weighing system, even under prolonged immersions conditions. Pack of 300ml.